10-330kV Oil current and voltage transformer
-
33-220kV SF6 gas CT &VT
-
3-36kV Electronic instrument transformer(sensor)
-
0.5-36kV Indoor epoxy resin CT&VT
-
0.5-66kV Outdoor epoxy resin(silicone rubber) CT VT
-
6-66kV Reactor
-
0.22-220kV Surge Arrester
-
Monopole Inductive Voltage Transformer
-
20-220kV Monopole Inductive Voltage Transformer
-
33kV-220kV Capacitor Voltage Transformer
-
10kV 11kV 33kV 35kV CT PT Combind transformer
66kV Oil Immersed Dead Tank Current Transformer
66kV Current Transformer Outdoor Oil Immersed Single Phase
Here we have 2 options for your choosing, dead tank (bottom tank) and live tank (top tank)
Dead tank is a traditional design which has mature technology, rich operation experience, good stability and low cost.
Live tank is a new and popular design, it is suitable for big current ratios, less material waste, high technology difficulty, good electrical field, compact structure and strong dynamic thermal ability.
Both of them we have rich manufacturing and operating experience.
Scope ◆It is outdoor, single phase and oil immersed hair-pin type current transformer, which is used for metering and relay protection of 66~69kV, 50 or 60Hz system. |
Standards ◆IEC 61869-1; IEC 61869-2 ◆GB 20840.1; GB 20840.2 |
Service conditions ◆Ambient temperature: -40~+45℃ ◆Altitude: ≤1000m (If above 1000m,the product will be customized according to user’s request) ◆Pollution level: II, III, IV |
Technica data
Rated frequency,Hz |
50; 60 |
|||||
Rated voltage,kV |
33or 35 |
66 or 69 |
110 or 115 |
132 or 138 |
150 |
220 or 230 |
Highest voltage for equipment, kV |
36 or 40.5 |
72.5 |
123 or 126 |
145 |
170 |
245 or 252 |
Rated power frequency withstand voltage, kV |
95 |
160 |
230 |
275 |
325 |
460 |
Rated lightning impulse voltage, kV |
200 |
350 |
550 |
650 |
750 |
1050 |
Flashover distance, mm |
385 |
700 |
1100 |
1300 |
1500 |
2100 |
Cree. distance, mm |
W1:810mm W2:1020mm W3:1260mm |
W1:1450 W2:1820 W3:2250 |
W1:2520 W2:3150 W3:3910 |
W1:2900 W2:3630 W3:4500 |
W1:3400 W2:4250 W3:5270 |
W1:5040 W2:6300 W3:7820 |
Mechanical load, N |
3000 |
3000 |
3000 |
3000 |
3000 |
4000 |
Rated primary current, A |
5~5000 |
|||||
Rated secondary current, A |
1; 2; 5 |
|||||
Accuracy class |
0.1; 0.2; 0.5; 0.2S; 0.5S; 0.5S; 5P; 10P; PX… |
|||||
Rated output(Recommended value), VA |
1A: 10~30 VA 2A: 10~30 VA 5A: 15~50VA |
|||||
Instrument security factor FS |
5; 10 |
|||||
Accuracy limit factors ALF |
10,15,20,25,30 |
|||||
Short-time thermal current(Maximum),kA |
50kA/3s |
Dalian Huayi Electric Power Electric Appliances Co., Ltd.
Address:
Pulandian District, Dalian City, Liaoning Province, China.
Tel:
0086-0411-83146175 (Domestic Sales) 0086-0411-83199993 (International sales)
Email:
HY83146175@163.com (Domestic sales) steven@cnhuayi.com.cn (International sales)
If you have any questions, please contact us
Traffic routes
Copyright :Dalian Huayi Electric Power Electric Appliances Co., Ltd. 辽ICP备06004612号 power by 300.cn